Skip to main content
Skip to main content
Mobility Aftermarket India
F 002 DG0 921

EPS 625 – Conventional pump test bench (HMI)

EPS 625 Conventional pump test bench

EPS 625 Conventional pump test bench

EPS 625 detail

EPS 625 Detail

EPS 625 Conventional pump test bench
EPS 625 detail

Powered by a 18.5 kW electrical drive, the EPS 625 is equipped with measuring glass technology for testing pumps with up to 12 cylinders.

The test bench features measuring glass technology, an electronically controlled stroke counter, and automatic test oil heating. Rotational speed, stroke rate, test oil temperature as well as actual values for testing are shown on a 5.7 inch LCD display.

More Information

  • Universal component: For testing conventional inline and distributor pumps from Bosch and other manufacturers
  • Large flywheel mass: For excellent and even running characteristics
  • Removable cover panels and modular design: For easy servicing and maintenance
  • Variable frequency converter drive: For high torque at lower speed ranges
  • 50-litre calibration test oil tank: For time efficiencies
  • Emergency stop buttons and anti-backlash coupling: For safety and accuracy
  • A perfect entry-level choice and solution: For economic capital and ongoing costs
Measurements (LxHxW) 2320 mm x 1730 mm x 950 mm
Measurements (LxHxW)
Weight
2320 mm x 1730 mm x 950 mm
950 kg of 415 Volt Version
1000 kg of 200 Volt Version
Measurements (LxHxW)
Voltage supply
2320 mm x 1730 mm x 950 mm
400 – 440 Volt/ 50 Hertz3 Phase
200 – 240 Volt/ 60 Hertz/3 Phase
Measurements (LxHxW)
Electrical driving motor
2320 mm x 1730 mm x 950 mm
Power = 18,5 kW
Current at max. power = 27 Amp
RPM Range = 50 - 4000 1/min
Measurements (LxHxW)
Torque
2320 mm x 1730 mm x 950 mm
0 – 1500 1/min = 115 Nm
1500 – 4000 1/min = 115 – 40 Nm
Measurements (LxHxW)
Measuring glass carrier with 12 measurement points
2320 mm x 1730 mm x 950 mm
Measuring glass small quantities = max. 44 ml
Measuring glass medium quantities = max. 260 ml
Axis height to injection pump coupling center = 125 +/- 0,1 mm
backlash free drive coupling clutch to ISO 2600 Nm/°
Measurements (LxHxW)
Stroke counter in HMI
2320 mm x 1730 mm x 950 mm
1 – 9999 Stroke variable
Measurements (LxHxW)
Delivery pump capacity
2320 mm x 1730 mm x 950 mm
Test oil supply low pressure 0 - 350 kPa
Delivery quantity 16,5 l / min
Test oil supply high pressure for Start of delivery/ Pre stroke adjustment 0 – 4 MPa (40 bar)
Delivery quantity 1,8 l / min
Test oil heating 2,5 kW
Control range heating 30 – 60 °C
Test oil supply high pressure for Start of delivery/ Pre stroke adjustment
Tank capacity
0 – 4 MPa (40 bar)
Delivery quantity 1,8 l / min
Test oil heating 2,5 kW
Control range heating 30 – 60 °C
Test oil tank = 50 l Test oil
Retaining capacity for contaminated test oil = 10 l
Required test oil: Divinol CAF as ISO 4113 CV AW
Test oil supply high pressure for Start of delivery/ Pre stroke adjustment
Display unit: HMI
0 – 4 MPa (40 bar)
Delivery quantity 1,8 l / min
Test oil heating 2,5 kW
Control range heating 30 – 60 °C
for pump speed = target / actual
for pump stroke counter = target / actual
for test oil temperature = target / actual
Color LCD – Display = 5,7 ‘‘
Rotatable HMI R/L 45° in both directions
Test oil supply high pressure for Start of delivery/ Pre stroke adjustment
Voltage supply for
0 – 4 MPa (40 bar)
Delivery quantity 1,8 l / min
Test oil heating 2,5 kW
Control range heating 30 – 60 °C
12 / 24V max. 7 Amp. for ELAB on VA and VE- distributor pumps or
Start/ Stop magnets on Inline pumps
Test oil supply high pressure for Start of delivery/ Pre stroke adjustment
Noise
0 – 4 MPa (40 bar)
Delivery quantity 1,8 l / min
Test oil heating 2,5 kW
Control range heating 30 – 60 °C
Sound pressure level max. 70 dB-A
  • Test bench with 5 different pressure gauges
  • Measuring glass carier with 12 measuring glass 44 ml and 12 measuring glass 260 ml
  • Display unit on test bench with HMI
  • Hydraulically supply and return line
  • Hydraulically measuring line for supply pressure on VE-Pumps or transfer pressure
  • backlash free drive coupling clutch
  • pressure control valve for MPC: For adjustment of MPC by air pressure
  • Pressure gauge:
    Low pressure indicator/suction pressure (0 to 150 kPa)
    Inlet pressure gauge (0 to 350 kPa)
    Boost pressure gauge (0 to 160 kPa)
    High pressure for start of conveying / cam offset measurement (0 to 4 MPa)
    Indoor pressure gauge VA/VE pump (0 to 1600 kPa)
  • Charging pressure control valve for adjusting the charging pressure
  • Pressure loading control valve for adjusting the delivery pump pressure/high pressure
Basic pump Set for conventional pumps
1 687 005 018
A-Pump set
1 687 005 019
M/MW-Pump set
1 687 005 020
P-Pump set
1 687 005 021
VE-Pump set
1 687 005 022
H/R-Pump set
1 687 005 023
Broad range of retrofit kits and repair tools