BAT 690 – battery charger
The universal BAT 690 is designed to charge all battery types, including; lead-acid, maintenance-free, standard, gel, fleece, AGM, EFB and Lithium Iron Phosphate (LFP) batteries. Using its soft charging phase, the BAT 690 can automatically charge heavily-depleted batteries.
Featuring as standard, both a backup mode, maintaining voltage supply to buffer data during battery replacement (e.g. car stereos, supply and control units, etc.) and floating mode, to keep the SOC of the battery and stabilise the vehicle’s electrical system when the engine is off. In floating mode, the battery charger can support the on-board power supply during any control unit updates.
More Information
Features and Benefits
- Automatic charging characteristics for different types of battery: Charge batteries easily and efficiently
- 90 A of continuous current output is able to charge all types of 12 V and 45A for 24 V battery: Truly universal charging
- Soft charging phase: For heavily depleted batteries
- Backup mode: Maintains voltage supply to buffer data during battery replacement
- Floating Mode: Power supply support during control unit updates
- Dot matrix display in 18 languages: Clear measurement readings
- USB port keeps battery charger software up-to-date: For futureproofing
- Charger holder for wall mounting: Convenient for extended charging periods
- Compact: Only 220 (w) x 115.5 (h) x 473 (d) for space saving in the workshop or in transit
- Robust housing: Durable for daily use
Technical Data
Max. Charge current intensity -12V -24V |
90 A 45 A |
Max. Charge current intensity -12V -24V
Length of the charging cable
|
90 A 45 A
2 x 3 m
|
Max. Charge current intensity -12V -24V
Cross-section charging cable
|
90 A 45 A
16 mm²
|
Max. Charge current intensity -12V -24V
Power input
|
90 A 45 A
Max. 1600 W
|
Max. Charge current intensity -12V -24V
Weight (without charging and power cable)
|
90 A 45 A
6,6 kg
|
Max. Charge current intensity -12V -24V
Charging characteristic
|
90 A 45 A
I1U1I2aI3aI3...
|
Max. Charge current intensity -12V -24V
Backup mode
|
90 A 45 A
12.0 V / 24.0 V max. 30 A
|
Floating-mode operation |
13.0 V / 26.0 V max. 90 A / 45 A |
Floating-mode operation
Function temperature range
|
13.0 V / 26.0 V max. 90 A / 45 A
-5°C – +45°C
|
Floating-mode operation
Main voltage
|
13.0 V / 26.0 V max. 90 A / 45 A
230 V, 50/60 Hz
|
Floating-mode operation
Battery nominal voltage
|
13.0 V / 26.0 V max. 90 A / 45 A
12 V / 24 V
|
Floating-mode operation
Protection type (DIN 40050)
|
13.0 V / 26.0 V max. 90 A / 45 A
IP 20 D
|
Floating-mode operation
Safety class (DIN 40530)
|
13.0 V / 26.0 V max. 90 A / 45 A
SK I
|
Floating-mode operation
Dimensions (W x H x D)
|
13.0 V / 26.0 V max. 90 A / 45 A
220 x 115,5 x 473 mm
|
Floating-mode operation
Emitted interference level (DIN 40839)
|
13.0 V / 26.0 V max. 90 A / 45 A
Class B
|
Scope of Delivery
- Battery charger
- Detachable charging cables
- Power cord
- Wall mount
- User manual
- Safety instructions
Special Accessories
Order no. | |
---|---|
Detachable charging cable, 5 m length, 16 mm² diameter
|
Order no.
1 687 011 535
|
Downloads
Segment Brochure (PDF)
|
|
Fact Sheet (PDF)
|
|
Manuals, updates and information
|